Specifikationstabel for EBSXB-D / ERLA-DW17

EBSXB16P50DG / ERLA16D2W17 EBSXB16P30DG / ERLA16DAW17 EBSXB16P30DG / ERLA16D2W17 EBSXB16P50DG / ERLA16DAW17 EBSXB16P30DF / ERLA16DAW17 EBSXB16P50DF / ERLA16DAW17 EBSXB16P30DF / ERLA16D2W17 EBSXB16P50DF / ERLA16D2W17
Indendørs enhed EBSXB16P50DG EBSXB16P30DG EBSXB16P30DG EBSXB16P50DG EBSXB16P30DF EBSXB16P50DF EBSXB16P30DF EBSXB16P50DF
Varmekapacitet Nom. kW 16.0 (1) 16.0 (1) 16.0 (1) 16.0 (1) 16.0 (1) 16.0 (1) 16.0 (1) 16.0 (1)
Kølekapacitet Nom. kW 13.6 (2) 13.6 (2) 13.6 (2) 13.6 (2) 13.6 (2) 13.6 (2) 13.6 (2) 13.6 (2)
Indgangseffekt Varme Nom. kW 3.53 (1) 3.53 (1) 3.53 (1) 3.53 (1) 3.53 (1) 3.53 (1) 3.53 (1) 3.53 (1)
  Køle Nom. kW 4.68 (2) 4.68 (2) 4.68 (2) 4.68 (2) 4.68 (2) 4.68 (2) 4.68 (2) 4.68 (2)
COP 4.53 (1) 4.53 (1) 4.53 (1) 4.53 (1) 4.53 (1) 4.53 (1) 4.53 (1) 4.53 (1)
EER 2.91 (2) 2.91 (2) 2.91 (2) 2.91 (2) 2.91 (2) 2.91 (2) 2.91 (2) 2.91 (2)
Opvarmning af varmt brugsvand Generelt Erklæret belastningsprofil   XL L L XL L XL L XL
  Gennemsnitsklima Energieffektivitetsklasse for vandopvarmning   A+ A+ A+ A+ A+ A+ A+ A+
Rumopvarmning Vandudgang på 55 °C ved gennemsnitsklima Generelt SCOP   3.35 3.35 3.35 3.35 3.35 3.35 3.35 3.35
      Klasse for effektivitet for rumopvarmning på helårsbasis   A++ A++ A++ A++ A++ A++ A++ A++
  Vandudgang på 35°C ved gennemsnitsklima Generelt SCOP   4.68 4.68 4.68 4.68 4.68 4.68 4.68 4.68
      Klasse for effektivitet for rumopvarmning på helårsbasis   A+++ A+++ A+++ A+++ A+++ A+++ A+++ A+++
Energieffektivitetsklasse Space Heating A+++ ~ D, Water Heating A+ ~ F Space Heating A+++ ~ D, Water Heating A+ ~ F Space Heating A+++ ~ D, Water Heating A+ ~ F Space Heating A+++ ~ D, Water Heating A+ ~ F Space Heating A+++ ~ D, Water Heating A+ ~ F Space Heating A+++ ~ D, Water Heating A+ ~ F Space Heating A+++ ~ D, Water Heating A+ ~ F Space Heating A+++ ~ D, Water Heating A+ ~ F
Bemærkninger (1) - Betingelse 1: køle Ta 35°C - LWE 18℃ (DT = 5°C); varmeTa DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Betingelse 1: køle Ta 35°C - LWE 18℃ (DT = 5°C); varmeTa DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Betingelse 1: køle Ta 35°C - LWE 18℃ (DT = 5°C); varmeTa DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Betingelse 1: køle Ta 35°C - LWE 18℃ (DT = 5°C); varmeTa DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Betingelse 1: køle Ta 35°C - LWE 18℃ (DT = 5°C); varmeTa DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Betingelse 1: køle Ta 35°C - LWE 18℃ (DT = 5°C); varmeTa DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Betingelse 1: køle Ta 35°C - LWE 18℃ (DT = 5°C); varmeTa DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Betingelse 1: køle Ta 35°C - LWE 18℃ (DT = 5°C); varmeTa DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (2) - Betingelse 2: køle Ta 35°C - LWE 7℃ (DT = 5°C); varmeTa DB/WB 7°C/6°C - LWC 45℃ (DT = 5°C) (2) - Betingelse 2: køle Ta 35°C - LWE 7℃ (DT = 5°C); varmeTa DB/WB 7°C/6°C - LWC 45℃ (DT = 5°C) (2) - Betingelse 2: køle Ta 35°C - LWE 7℃ (DT = 5°C); varmeTa DB/WB 7°C/6°C - LWC 45℃ (DT = 5°C) (2) - Betingelse 2: køle Ta 35°C - LWE 7℃ (DT = 5°C); varmeTa DB/WB 7°C/6°C - LWC 45℃ (DT = 5°C) (2) - Betingelse 2: køle Ta 35°C - LWE 7℃ (DT = 5°C); varmeTa DB/WB 7°C/6°C - LWC 45℃ (DT = 5°C) (2) - Betingelse 2: køle Ta 35°C - LWE 7℃ (DT = 5°C); varmeTa DB/WB 7°C/6°C - LWC 45℃ (DT = 5°C) (2) - Betingelse 2: køle Ta 35°C - LWE 7℃ (DT = 5°C); varmeTa DB/WB 7°C/6°C - LWC 45℃ (DT = 5°C) (2) - Betingelse 2: køle Ta 35°C - LWE 7℃ (DT = 5°C); varmeTa DB/WB 7°C/6°C - LWC 45℃ (DT = 5°C)