EHBH16CB3V / ERHQ014BAW17 EHBH16CB9W / ERHQ014BAW17
COP 4.24 (1), 3.22 (2) 4.24 (1), 3.22 (2)
Varmekapacitet Nom. kW 14.5 (1), 13.6 (2)
Strømforbrug Varme Nom. kW 3.42 (1), 4.21 (2)
Bemærkninger (1) - Betingelse 1: køle Ta 35°C - LWE 18℃ (DT = 5°C); varmeTa DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Betingelse 1: køle Ta 35°C - LWE 18℃ (DT = 5°C); varmeTa DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (2) - Betingelse 2: køle Ta 35°C - LWE 7℃ (DT = 5°C); varmeTa DB/WB 7°C/6°C - LWC 45℃ (DT = 5°C) (2) - Betingelse 2: køle Ta 35°C - LWE 7℃ (DT = 5°C); varmeTa DB/WB 7°C/6°C - LWC 45℃ (DT = 5°C)
  (3) - Tamb 35 °C - LWE 7 °C (DT=5 °C) (3) - Tamb 35 °C - LWE 7 °C (DT=5 °C)
  (4) - Tamb 35 °C - LWE 18℃ (DT=5 °C) (4) - Tamb 35 °C - LWE 18℃ (DT=5 °C)
  (5) - DB/WB 7 °C/6 °C-LWC 35 °C(DT=5 °C) (5) - DB/WB 7 °C/6 °C-LWC 35 °C(DT=5 °C)
  (6) - DB/WB 7° C/6° C - LWC 45℃ (Dt=5° C) (6) - DB/WB 7° C/6° C - LWC 45℃ (Dt=5° C)
Varmekapacitet Nom. kW   14.5 (1), 13.6 (2)
Indgangseffekt Varme Nom. kW   3.42 (1), 4.21 (2)
Rumopvarmning Vandudgang på 55 °C ved gennemsnitsklima Generelt SCOP     2.86
      Klasse for effektivitet for rumopvarmning på helårsbasis     A+
  Vandudgang på 35°C ved gennemsnitsklima Generelt SCOP     3.34
      Klasse for effektivitet for rumopvarmning på helårsbasis     A+
Energieffektivitetsklasse   Space Heating A+++ ~ D, Water Heating A+ ~ F